DATACAD LLC
Software for Architects
www.datacad.com
Simsbury, CT 06070
USA
Sales
(860) 217-0490 Main
(800) 394-2231 Sales
info@datacad.com
Technical Support
(860) 217-0567
help@datacad.com
Free DataCAD Forum
forum.datacad.com
Dear Valued Customer:
Thank you for your interest in DataCAD 24. As part of our dedication to continuous improvement and to
deliver the highest quality CADD products possible, this latest upgrade includes your most requested
enhancements. To get the most from DataCAD 24, please refer to the overview below. If you have any
questions about DataCAD 24, contact our technical support staff at help@datacad.com.
Thank you for supporting DATACAD,
![]()
Mark F. Madura
President/CEO
mark@datacad.com
DataCAD 24 delivers a broad set of performance and output enhancements for everyday drafting and large projects. This release improves the handling of complex drawings with extensive XREFs, Symbols, GoTo Views, and Multi-Scale Plotting Sheets; expands graphic capabilities with gradient and tiled bitmap fills; and modernizes printing with an expanded Pen Table, redesigned printer settings, and integrated DataCAD PDF Direct output.
Additional tools such as the XREF Tree, All Program Settings, PolyCleanup macro, expanded masking options, and new configuration settings provide easier customization and better troubleshooting throughout the program.
Where to find the new
feature
Helpful hints
DataCAD 15 through 24 share the same drawing file format. However, you must use the Save As command in the File menu to save files backward to older version formats (11 through 14).
DataCAD 24 includes significant performance improvements for large and complex drawings that make extensive use of XREFs, Self-XREFs, clipped XREFs, clipped Symbols, Symbols with Layer Control, GoTo Views, and Multi-Scale Plotting Sheets.
In drawings that contain many repeated references, DataCAD now reduces redundant processing of clipping extents, layer visibility, reference calculations, and related drawing data. These optimizations are especially noticeable in drawings with hundreds of self- references that use clipping and GoTo View linking.
Operations that previously could take several minutes or more may now complete in seconds, depending on the drawing.
The performance of large drawings has been improved in the following areas:
These under-the-hood changes can have a measurable day-to-day impact when working on larger projects.
Mouse Wheel Zoom has been updated to be smoother and more responsive to scrolling and direction changes.
The portion of the display pipeline that handles TrueType text has been optimized for faster
redraw of font outlines.
In this major update, DataCAD's graphics pipeline has been further enhanced to support greater versatility in construction and presentation documents.
Gradient fills blend two colors and opacity levels across a boundary. Sixteen presets are available: Horizontal, Vertical, Diagonal 1, Diagonal 2, Horizontal Center, Vertical Center, Diagonal Center, Diagonal Center 2, Left, Right, Top, Bottom, Top Left, Top Right, Bottom Left, and Bottom Right.
Bitmap fills can now be tiled at a user-defined size, allowing an image to repeat across a boundary like wallpaper at the interval you specify.
Enhanced fill properties can now be applied to TrueType text and smart wall cavities.
Inserted bitmaps can now be rotated directly in the drawing without having to embed them in a symbol or XREF.
The Pen Table can be configured for more than 15, and as many as 255 pens. From All Program Settings, set Pen Table Dialog : Max Pens to any value from 15 up to 255.
DataCAD's printing interface receives a major upgrade in this release. The Printer Settings dialog now provides direct access to the properties of the selected device driver and lets you set the output resolution in dots per inch (dpi).
DataCAD 24 includes a built-in PDF creation interface called DataCAD PDF Direct. Select this printer to control PDF output directly in DataCAD without relying on a third-party PDF driver.
When you open a drawing created prior to 24, DataCAD checks whether the printers saved with the drawing are still available. If a saved printer is unavailable, DataCAD automatically substitutes DataCAD PDF Direct. The first time you enter the Print menu, DataCAD displays a summary of the changes.
DataCAD attempts to preserve the original paper size using the best information available in the drawing:
Recovered paper dimensions are normalized so the short edge and long edge are stored consistently. The drawing’s saved layout orientation then determines whether the Quick Layout preview is horizontal or vertical.
The notification identifies:
Because older drawing formats did not always store printer margins or Check Print paper dimensions, the recovered layout may not exactly match the original printer. DataCAD PDF Direct uses the full physical sheet as its printable area.
The following dialogs are used to customize PDF output and these settings are saved on a per-drawing basis.
DataCAD PDF Direct provides a full complement of standard English and metric paper sizes. Output resolutions range from 72 to 4,800 dpi.
Previously, the selected printer driver determined DataCAD's PDF output format. With DataCAD PDF Direct, you can choose Vector (line-based) or Bitmap (raster) output. Bitmap output can be useful when you want to limit the editability of preliminary or submitted drawings.
Previously, the watermark feature was only available via Batch Plotting and File, PDF Watermark and the settings were only accessible by editing the DCADWIN.ini file. Now you can add a watermark from the Print menu directly and customize its properties from within your drawing. See the Watermark Settings dialog below.
Previously, you could create PDF layers from drawing layers or Multi-Scale Plotting details only through Batch Plotting or Print Preview. You can now set this option directly in the Print menu.
Previously, you could only add passwords and document restrictions to PDFs via Batch Plotting or via the File, PDF Security menu. Now you can establish these options directly from the Print menu. See PDF Restrictions dialog below.
Previously, document info was added automatically based on settings that were only accessible by editing keys in DCADWIN.ini. Now you can customize these fields on a per- drawing basis with DataCAD PDF Direct. See PDF Information Settings dialog below.
Though DataCAD 24 provides access to advanced PDF settings, you should not need to adjust most of them unless instructed by a DataCAD technician. One option and a related sub-option are worth your attention. Write TrueType (not vectors), and Embed Fonts. Instead of creating PDFs where TrueType text is converted to line segments and cannot be searched, DataCAD PDF Direct now adds TrueType font names in PDFs so the text is searchable. If you’re using a custom font that allows it, you can choose to embed the font definition in the PDF so the text displays correctly for someone who does not have the font. If you’re using a font that is included with Windows, this is not necessary as the local font definition will be used.
Sets the horizontal alignment of the image inside the bounding box. You can set the horizontal alignment to either Left, Center, or Right.
Sets the vertical alignment of the image. You can set the vertical alignment to either Top, Middle, or Bottom.
Sets the left edge of the bounding box (in percent of the page) that contains the image. A value of 50 will put the left edge of the watermark at the middle of the page.
Sets the top edge of the bounding box.
Sets the width of the bounding box (in percent of the page) that contains the image. A value of 50 will set the width of the image box to half the width of the page.
Sets the height of the bounding box.
Set the orientation of the image as you would like it to appear on the page. Stretch image to fit entire page Use this option to automatically fit the image as large as possible within the page extents.
Can be set to one of the following values: Normal, Multiply, Screen, Overlay, Darken, Lighten, ColorDodge, ColorBurn, HardLight, SoftLight, Difference, Exclusion, Hue, Saturation, Color, or Luminosity.
Sets transparency from 0 (completely opaque) to 100 (completely transparent).
Click the folder icon to select a bitmap to use as the watermark.
The PDF Information Settings dialog can be used to set the Title, Subject, Author, Keywords, and Creator of the document. The producer is DataCAD PDF Direct. DataCAD PDF Direct Advanced Settings
Check this option to add font names to the document instead of vectorized characters.
Check this option to embed font definitions in the document. This will increase the size of the document. Note: Not all fonts allow embedding. If you are using standard Windows fonts, embedding fonts is unnecessary.
To minimize file size, compression is enabled by default. Only disable this for troubleshooting purposes.
For best performance, command buffering is enabled by default. Disable it only for troubleshooting.
For the most reliable structuring of the graphic stack, reloading properties on a new stream is enabled by default. Only disable this for troubleshooting purposes.
Enabling this option increases the file size and the time required to generate the document. Enable it only for troubleshooting.
Check this option to preview the PDF in your default viewing application. Otherwise, DataCAD's built-in PDF Preview is used.
The temporary file is normally maintained in memory. Only enable this for troubleshooting purposes.
This option applies only to multi-page documents. Enable it only for troubleshooting.
This option should only be used if the graphic stack is being improperly formatted.
For troubleshooting purposes. This process may take some time with large files and can consume large amounts of memory.
The default value should be optimal. Only change this for troubleshooting purposes.
The default value of 80 is a good balance between size and quality. This applies to 24 bit images without transparency.
The default value of 5 is a good balance between size and quality. This applies to 32 bit images that can have transparency.
The default value is a good balance between file size and accuracy. A higher number may cause objects and graphics to be more accurately positioned but will increase the file size.
Sets the resolution of pattern brushes.
PDFium is the default rendering library. Only change this for troubleshooting purposes.
See PDF Restrictions in chapter 23 for more information.
When performing non-Copy or And Copy editing routines on smart walls (i.e., Move, Rotate, Mirror, and Stretch), associated doors, windows, and openings will automatically transform with the wall. New Associations are enabled by default. You can disable this behavior by setting the New Associations key in the [Smart Walls] section to False.
A new XREF Tree tool displays the reference hierarchy of the current drawing, making nested XREF relationships easier to understand and troubleshoot.
The scaling of the drawing form is now automatic. DataCAD queries the properties of your display and draws 1:1 at the current scale. You can customize the settings by unchecking Automatic in the Screen Calibration Dialog.
The drawing repair logic has been updated to be more fault tolerant when evaluating corrupt data. Previously, invalid data identified as a deletable offense was added directly to the "do you wish to delete" list. The evaluation of invalid drawing data now includes a "can repair" pass first, so fields that can be repaired by resetting them to zero or a default value are updated before the entity is sent to the final validation pass.
Four new options have been added:
DataCAD entities have a header that includes fields for color, line type, width, selection set membership, and many others. When this option is enabled, the values in each entity's header are validated, repaired if necessary, or flagged as deletable.
DataCAD layers have a header that includes fields for on/off state, entity count, grid origin, z-base, z-height, and many others. When this option is enabled, the values in each layer's header are validated and repaired if necessary. Layers with unrepairable data are not deleted.
DataCAD drawings contain more than 700 settings which include items like current dimension and text settings, the state of SWOTHLUD, printer settings, and many others. When this option is enabled, the values for each setting are validated and reset to a default value if necessary.
The testing and repair of selection sets was originally implemented in DataCAD 10. It’s rare for selection set data to become corrupt but this option allows you to validate them if necessary.
Flatten 3D entities has been updated to only affect 3D lines that are horizontal (same z values). Flatten 3D Lines in Symbols is now a separate option.
The Extraordinary Values dialog now exposes individual options for point (x, y, z) data, angles, text height, radius, and distance, in addition to z-base / z-height and reports the number of entities and corresponding extraordinary values found.
Three new sections allow you to skip the entity or all matching entities, replace the values in the entity or all matching entities, or delete the entity or all matching entities.
The audit report includes details about what invalid values were found and what the values were reset to.
A new All Program Settings button has been added to the Program Preferences dialog. It opens a tree view of DataCAD's program settings, including settings that are not represented on the standard preference tabs.
The Polyline Cleanup macro for DataCAD is a powerful tool designed to automate the cleanup and simplification of complex polylines, particularly those found in topographic maps and manufacturer symbol libraries. This macro offers options to remove redundant nodes, simplify geometries, flatten unnecessary bulges, and identify arc segments for conversion into bulges. The result is a more efficient and streamlined drawing.
Symbol Name and XREF Name options have been added to the Mask by Entity menu. When toggled On, a case-insensitive search string field appears. Any occurrence of the string in a Symbol or XREF name is considered a match. So, “flura” matches all of the following:
A Jump Gap option has been added to the Contour Search menu, allowing you to set the
maximum search distance around line segment endpoints when creating a closed boundary.
The Drawing Information dialog can now display the current Windows file associations for DataCAD file types. For example, you can confirm which copy of DCADWIN.exe is associated with AEC drawing files.
DataCAD 24 consolidates access to program settings through the All Program Settings tree in Program Preferences. Use this view to browse settings by section and adjust the behavior of new and existing features to suit your workflow.
Extended character codes are used when programming icon toolbars and keyboard macros. When using any of the following new extended character codes, you will use the syntax V= for a toolbar button which executes just the one single command, A=10XX# in a toolbar button sequence that contains more than one command, or 10XX# in a keyboard macro. For more information on toolbar programming, see the topic “Creating Custom Toolbars” in Chapter 30 of the DataCAD Reference Manual.
3057# Cut Wall On3058# Cut Wall Off3059# In Wall On3060# In Wall Off3061# One Layer On3062# One Layer Off3063# Any Layer On3064# Any Layer OffThank you for printing this page. Please feel free to contact us for further assistance. You can call our sales department at +1 (800) 394-2231, Monday through Friday from 8:00 a.m. to 5:00 p.m. Eastern time or send an e-mail message to info@datacad.com.